SUK pascite per stupra Terminal Clausus
SUK-1.5
Type | SUK-1.5 |
L/W/H | 4.2*43*41 mm |
Nominal sectionem crucis | 1.5 mm2 |
Ratum current | 17.5 A |
Rated voltage | 550 V |
Minimum sectione transversali (Rigida filum) | 0.14 mm2 |
Maxime sectione transversali (Rigida filum) | 1.5 mm2 |
Minimum sectione transversali (Molle filum) | 0.14 mm2 |
Maxime sectione transversali (Mollis filum) | 1.5 mm2 |
Cover | SUK-2.5XG |
DESULTOR | UFB1 10-4 |
Venalicium | ZB4 |
Stipare unitas | 150 STK |
Minimum Quantitas Ordinis | 150 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 6g |
Dimension
Wiring tabula
SUK-2.5
Dimension
Wiring tabula
Type | SUK-2.5 |
L/W/H | 5.2*43*46.5 mm |
Nominal sectionem crucis | 2.5 mm2 |
Ratum current | 32 A |
Rated voltage | 800 V |
Minimum sectione transversali (Rigida filum) | 0.2 mm2 |
Maxime sectione transversali (Rigida filum) | 4 mm2 |
Minimum sectione transversali (Molle filum) | 0.2 mm2 |
Maxime sectione transversali (Mollis filum) | 2.5 mm2 |
Cover | SUK-G(DUK) |
DESULTOR | UFB1 10-5/UEB 10-5 |
Venalicium | ZB5 |
Stipare unitas | 100 STK |
Minimum Quantitas Ordinis | 100 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 7g |
SUK-2.5X
Type | SUK-2.5X |
L/W/H | 6*43*41 mm |
Nominal sectionem crucis | 2.5 mm2 |
Ratum current | 32 A |
Rated voltage | 800 V |
Minimum sectione transversali (Rigida filum) | 0.2 mm2 |
Maxime sectione transversali (Rigida filum) | 4 mm2 |
Minimum sectione transversali (Molle filum) | 0.2 mm2 |
Maxime sectione transversali (Mollis filum) | 2.5 mm2 |
Cover | SUK-2.5XG |
DESULTOR | UFB1 10-5/UEB 10-5 |
Venalicium | ZB6 |
Stipare unitas | 100 STK |
Minimum Quantitas Ordinis | 100 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 7g |
Dimension
Wiring tabula
SUK-4
Dimension
Wiring tabula
Type | SUK-4 |
L/W/H | 6.2*43*46.5 mm |
Nominal sectionem crucis | 4 mm2 |
Ratum current | 41 A |
Rated voltage | 800 V |
Minimum sectione transversali (Rigida filum) | 0.2 mm2 |
Maxime sectione transversali (Rigida filum) | 6 mm2 |
Minimum sectione transversali (Molle filum) | 0.2 mm2 |
Maxime sectione transversali (Mollis filum) | 4 mm2 |
Cover | SUK-G(DUK) |
DESULTOR | UFB1 10-6/UEB 10-6 |
Venalicium | ZB6 |
Stipare unitas | 100 STK |
Minimum Quantitas Ordinis | 100 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 8.5g |
SUK-6
Type | SUK-6 |
L/W/H | 8.2*43*46 mm |
Nominal sectionem crucis | 6 mm2 |
Ratum current | 57 A |
Rated voltage | 800 V |
Minimum sectione transversali (Rigida filum) | 0.2 mm2 |
Maxime sectione transversali (Rigida filum) | 10 mm2 |
Minimum sectione transversali (Molle filum) | 0.2 mm2 |
Maxime sectione transversali (Mollis filum) | 6 mm2 |
Cover | SUK-G(DUK) |
DESULTOR | UFB1 10-8/ UEB 10-8 |
Venalicium | ZB8 |
Stipare unitas | 100 STK |
Minimum Quantitas Ordinis | 100 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 13g |
Dimension
Wiring tabula
SUK-10
Dimension
Wiring tabula
Type | SUK-10 |
L/W/H | 10.2*43*46.5 mm |
Nominal sectionem crucis | 10 mm2 |
Ratum current | 76 A |
Rated voltage | 800 V |
Minimum sectione transversali (Rigida filum) | 0.5 mm2 |
Maxime sectione transversali (Rigida filum) | 16 mm2 |
Minimum sectione transversali (Molle filum) | 0.5 mm2 |
Maxime sectione transversali (Mollis filum) | 10 mm2 |
Cover | SUK-G(DUK) |
DESULTOR | UFB1 10-10/UEB 10-10 |
Venalicium | ZB10 |
Stipare unitas | 50 STK |
Minimum Quantitas Ordinis | 50 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 16g |
SUK-16
Type | SUK-16 |
L/W/H | 12.2*42.5*51 mm |
Nominal sectionem crucis | 16 mm2 |
Ratum current | 101 A |
Rated voltage | 800 V |
Minimum sectione transversali (Rigida filum) | 2.5 mm2 |
Maxime sectione transversali (Rigida filum) | 25 mm2 |
Minimum sectione transversali (Molle filum) | 4 mm2 |
Maxime sectione transversali (Mollis filum) | 16 mm2 |
Cover | SUK-16G |
DESULTOR | UFB1 10-12/UEB 10-12 |
Venalicium | ZB10 |
Stipare unitas | 50 STK |
Minimum Quantitas Ordinis | 50 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 21.5g |
Dimension
Wiring tabula
SUK-35
Dimension
Wiring tabula
Type | SUK-35 |
L/W/H | 15.2*51*57.5 mm |
Nominal sectionem crucis | 35 mm2 |
Ratum current | 125 A |
Rated voltage | M V |
Minimum sectione transversali (Rigida filum) | 0.75 mm2 |
Maxime sectione transversali (Rigida filum) | 50 mm2 |
Minimum sectione transversali (Molle filum) | 0.75 mm2 |
Maxime sectione transversali (Mollis filum) | 35 mm2 |
Cover | / |
DESULTOR | UFB1 2-15/ UEB 2-15 |
Venalicium | ZB10 |
Stipare unitas | 18 STK |
Minimum Quantitas Ordinis | 18 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 55.5g |
SUK-35I
Type | SUK-35I |
L/W/H | 15.2*55*50 mm |
Nominal sectionem crucis | 35 mm2 |
Ratum current | 125 A |
Rated voltage | M V |
Minimum sectione transversali (Rigida filum) | 4 mm2 |
Maxime sectione transversali (Rigida filum) | 50 mm2 |
Minimum sectione transversali (Molle filum) | 4 mm2 |
Maxime sectione transversali (Mollis filum) | 35 mm2 |
Cover | / |
DESULTOR | UFB1 2-15/ UEB 2-15 |
Venalicium | ZB10 |
Stipare unitas | 18 STK |
Minimum Quantitas Ordinis | 18 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 43.5g |
Dimension
Wiring tabula