SUK Multi-Level Terminal Clausus
SUK-2.5 2-2
Type | SUK-2.5/2-2 duplex gradus terminalis clausus |
L/W/H | 5.2*56.5*61.5 mm |
Nominal sectionem crucis | 2.5 mm2 |
Ratum current | 24 A |
Rated voltage | D V |
Minimum sectione transversali (Rigida filum) | 0.2 mm2 |
Maxime sectione transversali (Rigida filum) | 4 mm2 |
Minimum sectione transversali (Mollis filum) | 0.2 mm2 |
Maxime sectione transversali (Mollis filum) | 2.5 mm2 |
Cover | SUK-4/2-2G |
DESULTOR | UFB1 10-5/UEB 10-5 |
Venalicium | ZB5 |
Stipare unitas | 120 STK |
Minimum Quantitas Ordinis | 120 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 14.5g |
Dimension
Wiring tabula
SUK-2.5 3-3
Dimension
Wiring tabula
Type | SUK-2.5M/2-2 duplex gradus terminalis clausus |
L/W/H | 5.2*62.5*47 mm |
Nominal sectionem crucis | 2.5 mm2 |
Ratum current | 24 A |
Rated voltage | D V |
Minimum sectione transversali (Rigida filum) | 0.2 mm2 |
Maxime sectione transversali (Rigida filum) | 4 mm2 |
Minimum sectione transversali (Mollis filum) | 0.2 mm2 |
Maxime sectione transversali (Mollis filum) | 2.5 mm2 |
Cover | SUK-2.5M/2G |
DESULTOR | UFB1 10-5/UEB 10-5 |
Venalicium | ZB5 |
Stipare unitas | 120 STK |
Minimum Quantitas Ordinis | 120 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 12.5g |
SUK-2.5M 2-2
Type | SUK-4/2-2 duplex-gradu terminalis clausus |
L/W/H | 6.2*56.5*61.5 mm |
Nominal sectionem crucis | 4 mm2 |
Ratum current | 32 A |
Rated voltage | D V |
Minimum sectione transversali (Rigida filum) | 0.2 mm2 |
Maxime sectione transversali (Rigida filum) | 4 mm2 |
Minimum sectione transversali (Mollis filum) | 0.2 mm2 |
Maxime sectione transversali (Mollis filum) | 4 mm2 |
Cover | SUK-4/2-2G |
DESULTOR | UFB1 10-6/UEB 10-6 |
Venalicium | ZB6 |
Stipare unitas | 100 STK |
Minimum Quantitas Ordinis | 100 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 14.5g |
Dimension
Wiring tabula
SUK-4 2-2
Dimension
Wiring tabula
Type | SUK-4/2-2L duplex gradus terminalis clausus |
L/W/H | 6.2*56.5*67.5 mm |
Nominal sectionem crucis | 4 mm2 |
Ratum current | 32 A |
Rated voltage | D V |
Minimum sectione transversali (Rigida filum) | 0.2 mm2 |
Maxime sectione transversali (Rigida filum) | 4 mm2 |
Minimum sectione transversali (Mollis filum) | 0.2 mm2 |
Maxime sectione transversali (Mollis filum) | 4 mm2 |
Cover | SUK-4/2-2G |
DESULTOR | UFB1 10-6/UEB 10-6 |
Venalicium | ZB6 |
Stipare unitas | 80 STK |
Minimum Quantitas Ordinis | 80 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 15g |
SUK-4 2-2L
Type | SUK-2.5/3-3 triplici gradu terminali clausus |
L/W/H | 6.2*72.5*54 mm |
Nominal sectionem crucis | 2.5 mm2 |
Ratum current | 30 A |
Rated voltage | 250 V |
Minimum sectione transversali (Rigida filum) | 0.2 mm2 |
Maxime sectione transversali (Rigida filum) | 4 mm2 |
Minimum sectione transversali (Mollis filum) | 0.2 mm2 |
Maxime sectione transversali (Mollis filum) | 2.5 mm2 |
Cover | / |
DESULTOR | UFB1 10-6/UEB 10-6 |
Venalicium | ZB6 |
Stipare unitas | 80 STK |
Minimum Quantitas Ordinis | 80 STK |
Pondus uniuscuiusque (non includit sarcina arca) | 20.5g |
Dimension
Wiring tabula